This unit is both a two-channel and multi-range device.23 Interchangeable pressure modules
This unit is both a two-channel and multi-range device. Changing ranges is as easy as plugging in new input modules, which can be done even while the unit is powered up. The signals from installed modules are automatically recognized and assigned to the proper channel. External pressure connection is made by a 1/8" FNPT 316SS connector. This plug-in design also simplifies maintenance. Only the input modules themselves require re-calibration. You send only the out-of-calibration modules back to the shop, while still using the unit in the field.
When operated in the documenting mode, the unit works with many popular calibrating software packages including Emerson AMS, Cornerstone, and Honeywell Document. Instrument tag numbers and calibration routines can be downloaded and used for field calibration. When tests are completed, the data can be uploaded back into the host calibration software.
Features
Intrinsically safe design for use in Class I Div 2, Groups A, B, C & D hardous areas
0 to ±249.99 mVDC; 0 to ±2.4999 and ±24.999 VDC; 0 to 24.999
and 149.99 mADC
Environmental
Temperature/humidity
-20°C to 50°C (operating) / 0 to 95%
Alarm trip detect
Wet contact input, 48 VDC max.
Power supply
Rechargeable NiCd external battery pack
Charging
16 hours maximum; fast charge battery optional, 90 min. charge time
Size/weight
4.3" x 7.5" x 2.4" (70mm x 190mm x 60mm)/ 1.5 kg with carrying case and accessories
CAT NO.
MODEL
DEscRIPTION
AVAIL
PRICE
BE325
910325-70
Beta Intrinsically Safe Pressure Calibrator
Yes
2,797,200
Iincludes: Voltage/current input module, rechargeable NiCd, one set of test leads, trickle charger, instruction manual, vinyl carrying case, 9-pin D shell to 9-pin D shell serial cable.
BE3251
325K
Beta Kit – includes Gauge and one pressure module (please specify pressure range)
Yes
3,877,200
Iincludes: Voltage/current input module, rechargeable NiCd, one set of test leads, trickle charger, instruction manual, vinyl carrying case, 9-pin D shell to 9-pin D shell serial cable.
BE3252
917007-001
Spare DC Input Module
Yes
1,285,200
BE3700
917004-001
Spare Intrinsically Safe Battery Pack
Yes
507,600
BE910331-005
910331-005
OPTIONAL Module, 0 to 5 PSIG (0 to 350 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910331-007
910331-007
OPTIONAL Module, 0 to 7.2 PSIG (0 to 500 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910331-010
910331-010
OPTIONAL Module, 0 to 10 PSIG (0 to 700 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910331-030
910331-030
OPTIONAL Module, 0 to 30 PSIG (0 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910331-050
910331-050
OPTIONAL Module, 0 to 50 PSIG (0 to 3.5 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910331-100
910331-100
OPTIONAL Module, 0 to 100 PSIG (0 to 7 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910331-150
910331-150
OPTIONAL Module, 0 to 150 PSIG (0 to 10 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910326-300
910326-300
OPTIONAL Module, 0 to 300 PSIG (0 to 20 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910326-301
910326-301
OPTIONAL Module, 0 to 1,000 PSIG (0 to 70 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910326-315
910326-315
OPTIONAL Module, 0 to 1,500 PSIG (0 to 100 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910326-303
910326-303
OPTIONAL Module, 0 to 3,000 PSIG (0 to 200 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910326-305
910326-305
OPTIONAL Module, 0 to 5,000 PSIG (0 to 350 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910329-005
910329-005
OPTIONAL Module, 0 to 5 PSID (0 to 350 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910329-030
910329-030
OPTIONAL Module, 0 to 30 PSID (0 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910329-050
910329-050
OPTIONAL Module, 0 to 50 PSID (0 to 3.5 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910327-005
910327-005
OPTIONAL Module, 0 to -5 PSIG (0 to -350 mBAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910327-015
910327-015
OPTIONAL Module, 0 to 7-15 PSIG (0 to -1 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910332-015
910332-015
OPTIONAL Module, 0 to 15 PSIA (0 to 1 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910332-030
910332-030
OPTIONAL Module, 0 to 30 PSIA (0 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910332-050
910332-050
OPTIONAL Module, 0 to 30 PSIA (0 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910332-100
910332-100
OPTIONAL Module, 0 to 100 PSIA (0 to 7 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910333-015
910333-015
OPTIONAL Module, -15 to 15 PSG (-1 to 1 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200
BE910333-030
910333-030
OPTIONAL Module, -15 to 30 PSG (-1 to 2 BAR) FOR Beta Intrinsically Safe Documenting Process Calibrator
Yes
1,501,200