Tactile keypad provides readout in H2O, Hg, PSI, kPa, mmHg, mBAR, cmH2O, and BARS.
Simple to Use Tactile keypad provides readout in H2O, Hg, PSI, kPa, mmHg, mBAR, cmH2O, and BARS. One user-defined scale can also be programmmed. Temperature scaling for H2O measurements is selectable among 4°C, 20°C, and 60°F.
Test Pressure Switches Min/max memory reads out the highest and lowest measurements. Trip Detect monitors the electrical measurement for a change of state, and freezes the last pressure measurement on the display. The unit can also display input vs. output as a percent error. A damping function that averages the last 16 readings to compensate for pulsating pressures is built in.
Each unit includes: Set of test leads, internal NiCd battery pack, battery charger, carrying case, manufacturer’s NIST traceable certificate, and instruction manual.
This unit is available in a CSA intrinsically safe version for Class 1 Groups A, B, C, and D.
Features
Choice of dry (non-isolated) or wet (isolated) sensors
Intrinsically safe option (see ordering Information)
Single or dual sensor modes
Also reads mA and Volts
0.1% or better accuracy
Five (5) digit resolution
SPECIFICATIONS – Range Selection Chart
Range
Range Code
Gauge
Dry
Wet
0.3 PSIG
01
NA
1
02
NA
5
03
60
7.2
22
61
10
NA
62
15
24
63
30
04
64
50
05
65
100
06
66
150
NA
67
300
07
68
1,000
08
08
1,500
23
23
3,000
09
09
5,000
10
10
Vacuum
-1 PSI
11
NA
-5
12
NA
-15
13
NA
Absolute
15 PSIA
14
50
30
15
51
50
16
52
100
NA
53
Differential
1 PSID
17
NA
5
18
NA
30
19
NA
50
20
NA
Note: Dry indicates the sensor is approved for use with dry media (gasses) only. Wet indicates the sensor is approved for use with any media compatible with 316 SS.
Accuracy
0.07 % rdg + 0.03% of scale + 1 digit or better, all PSI ranges
Resolution
50,000 counts max. depending on range and engineering units
mA Input
0-20 mA and 0-50 mA ranges
V Input
0-30 VDC range
mA/V Accuracy
0.025% ±1 LSD
Media Compatibility
Non-corrosive liquids and gasses; liquids not recommended for low pressure (0.3-100 PSIG) ranges
Pressure Fittings
1/8" FNTP 316 SS
Display
Two-line, 32 character alphanumeric LCD
Power Supply
Four AA rechargeable NiCd batteries
CAT NO.
MODEL
DEscRIPTION
AVAIL
PRICE
BE3201
320-*-70-IS
Single Sensor, 70VAC Charger, no loop supply, intrinsically safe
Yes
3,769,200
Different models are single range only.
BE3202
320-*-220-01-IS
Single Sensor, 220VAC Charger, no loop supply, intrinsically safe
Yes
3,769,200
Note: For Single sensor Units, "Left Port" selection is mandatory. For Dual Sensor units, "Left Port" must be the lower of the two ranegs selected.
BE3203
320-*-70-02
Single Sensor, 70VAC charger, loop supply
Yes
3,823,200
Note: Single Sensor units, "Left Port" selection is mandatory. For Dual Sensor units, "Left Port" must be the lower of the two ranges selected. Difffernt models are single range only.
BE3204
320-*-220-02
Single Sensor, 220VAC Charger, loop supply
Yes
3,823,200
Note: For Single Sensor units, "Left Port" selection is mandatory. For Dual Sensors units, "Left Port" must be the lower of the two ranges selected. Different models are single range only.
BE3205
320-*-70-01
Single Sensor, 70VAC charger
Yes
3,013,200
Note: For Single Sensor units, "Left Port" selection is mandatory. For Dual Sensor units, "Left Port" must be the lower of the two ranges selected. Different models are single range only.
BE3206
320-*-220-01
Single Senso, 220VAC charger
Yes
3,013,200
Note: For Single Sensor units, "Left Port" is mandatory. For Dual Sensor units, "Left Port" must be the lower if the two ranges selected. Different models are single range only.
BE3207
320-*-*-70-01-IS
Dual Sensor, 70VAC Charger, no loop supply, intrinsically safe
Yes
5,065,200
Note: For Single Sensor units, "Left Port" is mandatory. For Dual Sensor units, "Left Port" must be the lower of the two ranges selected. Different models are single range only.
BE3208
320-*-*-220-01-IS
Dual Sensor, 220VAC Charger, no loop supply, intrinsically safe
Yes
5,065,200
Note: For Single Sensor units, "Left Port" is mandatory. For Dual Sensor units, "Left Port" must be the lower of the two ranges selected. Different models are single range only.
BE3209
320-*-*-70-02
Dual Sensor, 70VAC charger, loop supply
Yes
5,119,200
Note: For Single Sensor units, "Left Port" is mandatory. For Dual Sensor units, "Left Port" must be the lower of the twp ranges selected. Different models are single range only.
BE3210
320-*-*-220-02
Dual Sensor, 220VAC Charger, loop supply
Yes
5,119,200
Note:For Single Sensor units, "Left Port" is mandatory. For Dual Sensor units, "Left Port" must be the lowest of the two ranges selected. Different models are single range only.
BE3211
320-*-*-70-01
Dual Sensor, 70VAC charger
Yes
4,309,200
Note: For Single Sensor units, "Left Port" is mandatory. For Dual Sensor units, "Left Port" must be the lower of the two ranges selected. Differnet models are single range only.
BE3212
320-*-*-220-01
Dual Sensor, 220VAC charger
Yes
4,309,200
Note: For Single Sensor units, "Left Port" is mandatory. For Dual Sensor units, "Left Port" must be the lower of the two ranges selected. Different models are single range only.
번호
제목
작성자
작성일
평가점수
이 상품에 대한 사용후기가 아직 없습니다.
사용후기를 작성해 주시면 다른 분들께 많은 도움이 됩니다.